posted on 2024-11-03, 15:09 authored by Vivek Sharma, M Hossain, Syed Muhammad Nawazish AliSyed Muhammad Nawazish Ali
The Z-source inverter (ZSI) is getting popular for induction motor drives as it provides single-stage power conversion with voltage buck-boost ability. Recent surveys have reported that inverters are prone to failure due to internal faults on power semiconductor devices which significantly degrades the overall systems performance. The analysis and diagnosis of faults are significantly important for ensuring reliable operation of a drive systems. This paper rigorously analyzes effects of internal faults on a ZSI-fed single-phase induction motor drive system using MATLAB/Simulink. This study proposes a fault protection technique using bidirectional converter to facilitate post fault operation of inverter drives. The simulation circuits with the related harmonic spectrum are presented after introducing an open circuit fault and a short circuit fault in a drive system with and without a protection circuit. From systematic analyses it is found that fault occurrence leads to harmonic distortion to a significant level in the proposed drive system and therefore, affects the systems efficiency. The proposed fault protection technique proves to be an effective method to reduce harmonics in the drive system during a fault occurrence. THe FFT spectrum results are tabulated and compared.

History

Start page

1

End page

6

Total pages

6

Outlet

Proceedings of the IEEE Region Ten Symposium

Name of conference

TENSYMP 2018

Publisher

IEEE

Place published

United States

Start date

2018-07-04

End date

2018-07-06

Language

English

Copyright

© 2018 by IEEE. All Rights Reserved.

Former Identifier

2006119479

Esploro creation date

2022-12-04

Usage metrics

    Scholarly Works

    Exports

    RefWorks
    BibTeX
    Ref. manager
    Endnote
    DataCite
    NLM
    DC