RMIT University
Browse

Bi-modal system-on-chip platform for bilirubin monitoring by using photometric and temporal degradation approaches

journal contribution
posted on 2024-11-03, 09:26 authored by Jean Pierre NdabakuranyeJean Pierre Ndabakuranye, Steven Prawer, Arman AhnoodArman Ahnood
Hyperbilirubinemia in infants and cirrhosis in adults remain major global causes of sickness and death, predominantly for people living in areas with poor or limited healthcare resources. Clinically, the two conditions require measuring levels of bilirubin in blood for diagnostic and prognostic purposes. While the existing techniques provide the most comprehensive pathology-lab results, they suffer from complexity and size requirements, and measurements are impractical for point-of-Care (PoC) testing. Furthermore, the existing transcutaneous devices (for neonates) are pricey, preventing the possibility of dissemination for home health care applications. This study uses an integrated and all-inclusive miniature (3.5 × 7.0 mm) system-on-chip platform (MAX86916) to measure bilirubin concentration. On MAX86916 embeds two optical sources (blue LED and green LED) which are utilized for dual-wavelength (DWL) measurement. Furthermore, a new photodegradation kinetics approach was incorporated with DWL approach to enhance the overall system reliability and accuracy. Bilirubin concentration was extracted by monitoring the optical transmission and the photodegradation responses. Measurements were carried out on porcine blood, the best existing surrogate for human blood, and the concentration of bilirubin was maintained within the range of pathophysiological levels (1 mg/dL to 50 mg/dL). The measurement could require a volume of less than 10 µL of a blood sample. Our findings show a good system accuracy of ∼ ±10 % and lay the groundwork for PoC bilirubin monitoring, primarily for hyperbilirubinemia and cirrhosis out of clinics and hospitals.

History

Related Materials

  1. 1.
    DOI - Is published in 10.1016/j.bspc.2023.104848
  2. 2.
    ISSN - Is published in 17468094

Journal

Biomedical Signal Processing and Control

Volume

85

Number

104848

Start page

1

End page

7

Total pages

7

Publisher

Elsevier BV

Place published

Netherlands

Language

English

Copyright

© 2023 The Author(s). Published by Elsevier Ltd. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/bync-nd/4.0/).

Former Identifier

2006122928

Esploro creation date

2023-06-22

Usage metrics

    Scholarly Works

    Exports

    RefWorks
    BibTeX
    Ref. manager
    Endnote
    DataCite
    NLM
    DC