RMIT University
Browse

Combining environmental isotopes with Contaminants of Emerging Concern (CECs) to characterise wastewater derived impacts on groundwater quality

journal contribution
posted on 2024-11-02, 13:13 authored by William McCance, Oliver JonesOliver Jones, Dioni Cendon, Mark Edwards, Aravind Surapaneni, Sreenivasulu Chadalavada, Songtao Wang, Matthew CurrellMatthew Currell
The potential for Wastewater Treatment Plants (WWTPs) to cause adverse impacts to groundwater quality is a major global environmental challenge. Robust and sensitive techniques are required to characterise these impacts, particularly in settings with multiple potential contaminant sources (e.g. agricultural vs. site-derived). Stable (δ2HH2O, δ18OH2O, δ15NNO3, δ18ONO3 and δ13CDIC) and radioactive (3H and 14C) isotopes were used in conjunction with three Contaminants of Emerging Concern (CECs) - carbamazepine, simazine and sulfamethoxazole - to discriminate between multiple potential contamination sources at an Australian WWTP. The radioactive isotope tritium provided a sensitive indicator of recent (post-1990s) leakage, with groundwater activities between 0.68 and 1.83 TU, suggesting WWTP infrastructure (activities between 1.65 and 2.41) acted as a recharge ‘window’, inputting treated or partially treated effluent to the underlying groundwater system. This was corroborated by water stable isotopes, which showed clear demarcation between δ18OH2O and δ2HH2O in background groundwater (δ18OH2O and δ2HH2O values of approximately −5 and −28‰, respectively) and those associated with on-site wastewater (median δ18OH2O and δ2HH2O values of −1.2 and −7.6‰, respectively), with groundwater down-gradient of the plant plotting on a mixing line between these values. The CECs, particularly the carbamazepine:simazine ratio, provided a means to further distinguish wastewater impacts from other sources, with groundwater down-gradient of the plant reporting elevated ratios (median of 0.98) compared to those up-gradient (median of 0.11). Distinctive CEC ratios in impacted groundwater close to the WWTP (∼3.0) and further down-gradient (2.7–9.3) are interpreted to represent a change in composition over time (i.e., recent vs. legacy contamination), consistent with the site development timeline and possible changes in effluent composition resulting from infrastructure upgrades over time. The

History

Journal

Water Research

Volume

182

Number

116036

Start page

1

End page

15

Total pages

15

Publisher

Elsevier

Place published

United Kingdom

Language

English

Copyright

© 2020 Elsevier Ltd. All rights reserved.

Former Identifier

2006100607

Esploro creation date

2020-09-08