RMIT University
Browse

Computational investigation of nasal surface coverage from squeeze bottle and Neti Pot saline irrigation flow

journal contribution
posted on 2024-11-02, 22:22 authored by Hana Salati, Mehrdad Khamooshi, David Fletcher, Kiao InthavongKiao Inthavong
Background and objective: Nasal saline irrigation is a common therapy for inflammatory nasal and paranasal disease or for managing post nasal and sinus surgery recovery. Two common irrigation devices include the netipot and squeeze bottles, where anecdotally, these devices alleviate congestion, facial pain, and pressure. However, a quantitative evaluation of these devices’ performance and the fluid dynamics responsible for the irrigation distribution through the nose is lacking. This study tracked the liquid surface coverage and wall shear stresses during nasal saline irrigation produced from a Neti Pot and squeeze bottle. Methods: This study used transient computational fluid dynamics (CFD) simulations to investigate the saline irrigation flow field in a subject-specific sinonasal model. The computational nasal cavity model was constructed from a high-resolution computed tomography scan (CT). The irrigation procedure applied a head position tilted at 90° forward using an 80 ml squeeze bottle and 120 ml Neti Pot. Results: The results from a single sinonasal model demonstrated that the Neti Pot irrigation was more effective in delivering saline solution to the nasal cavity on the contralateral side of irrigation due to typically larger volumes but at the expense of reduced flow and shearing rates, as the flow entered under gravitational forces. The squeeze bottle irrigation provided greater surface coverage on the side of irrigation. Conclusions: The results from the single patient model, demonstrated the Neti Pot increased surface coverage in the paranasal sinuses. Reducing the jet diameter may aid the direct targeting of a specific region at the side of irrigation by preventing the impingement of the jet to the nasal passage surface and redirection of the flow. Evaluating this performance across a wider cohort of patients can strengthen the findings.

History

Journal

Computer Methods and Programs in Biomedicine

Volume

227

Number

107223

Start page

1

End page

10

Total pages

10

Publisher

Elsevier Ireland Ltd

Place published

Clare, Ireland

Language

English

Copyright

© 2022 Elsevier B.V. All rights reserved.

Former Identifier

2006119390

Esploro creation date

2023-03-01

Usage metrics

    Scholarly Works

    Exports

    RefWorks
    BibTeX
    Ref. manager
    Endnote
    DataCite
    NLM
    DC