RMIT University
Browse

Energy spectra considerations for synchrotron radiotherapy trials on the ID17 bio-medical beamline at the European Synchrotron Radiation Facility

journal contribution
posted on 2024-11-01, 23:12 authored by Jeffrey Crosbie
The aim of this study was to validate the kilovoltage X-ray energy spectrum on the ID17 beamline at the European Synchrotron Radiation Facility (ESRF). The purpose of such validation was to provide an accurate energy spectrum as the input to a computerized treatment planning system, which will be used in synchrotron microbeam radiotherapy trials at the ESRF. Calculated and measured energy spectra on ID17 have been reported previously but recent additions and safety modifications to the beamline for veterinary trials warranted a fresh investigation. The authors used an established methodology to compare X-ray attenuation measurements in copper sheets (referred to as half value layer measurements in the radiotherapy field) with the predictions of a theoretical model. A cylindrical ionization chamber in air was used to record the relative attenuation of the X-ray beam intensity by increasing thicknesses of high-purity copper sheets. The authors measured the half value layers in copper for two beamline configurations, which corresponded to differing spectral conditions. The authors obtained good agreement between the measured and predicted half value layers for the two beamline configurations. The measured first half value layer was 1.754 ± 0.035 mm Cu and 1.962 ± 0.039 mm Cu for the two spectral conditions, compared with theoretical predictions of 1.763 ± 0.039 mm Cu and 1.984 ± 0.044 mm Cu, respectively. The calculated mean energies for the two conditions were 105 keV and 110 keV and there was not a substantial difference in the calculated percentage depth dose curves in water between the different spectral conditions. The authors observed a difference between their calculated energy spectra and the spectra previously reported by other authors, particularly at energies greater than 100 keV. The validation of the beam spectrum by the copper half value layer measurements means the authors can provide an accurate spectrum as

Funding

X-Tream: A realtime X-ray treatment monitoring and dosimetry system for submillimetric radiosurgery

National Health and Medical Research Council

Find out more...

Translating synchrotron microbeam radiation therapy into a clinical reality for cancer patients

National Health and Medical Research Council

Find out more...

History

Related Materials

  1. 1.
    DOI - Is published in 10.1107/S1600577515008115
  2. 2.
    ISSN - Is published in 09090495

Journal

Journal of Synchrotron Radiation

Volume

22

Start page

1035

End page

1041

Total pages

7

Publisher

Wiley-Blackwell Publishing

Place published

United Kingdom

Language

English

Copyright

© 2015 International Union of Crystallography.

Former Identifier

2006057364

Esploro creation date

2020-06-22

Fedora creation date

2016-07-07

Usage metrics

    Scholarly Works

    Exports

    RefWorks
    BibTeX
    Ref. manager
    Endnote
    DataCite
    NLM
    DC