While reverse osmosis (RO) technology is playing an increasingly important role in the reclamation of municipal wastewater, safe disposal of the resulting RO concentrate (ROC), which can have high levels of effluent organic pollutants, remains a challenge to the water industry. The potential of UVC/H(2)O(2) treatment for degrading the organic pollutants and increasing their biodegradability has been demonstrated in several studies, and in this work the impact of the water quality variables pH, salinity and initial organic concentration on the UVC/H(2)O(2) (3mM) treatment of a municipal ROC was investigated. The reduction in chemical oxygen demand and dissolved organic carbon was markedly faster and greater under acidic conditions, and the treatment performance was apparently not affected by salinity as increasing the ROC salinity 4-fold had only minimal impact on organics reduction. The biodegradability of the ROC (as indicated by biodegradable dissolved organic carbon (BDOC) level) was at least doubled after 2h UVC/H(2)O(2) treatment under various reaction conditions. However, the production of biodegradable intermediates was limited after 30min treatment, which was associated with the depletion of the conjugated compounds. Overall, more than 80% of the DOC was removed after 2h UVC/3mM H(2)O(2) treatment followed by biological treatment (BDOC test) for the ROC at pH 4-8.5 and electrical conductivity up to 11.16mS/cm. However, shorter UV irradiation time gave markedly higher energy efficiency (e.g., EE/O 50kWh/m(3) at 30min (63% DOC removal) cf. 112kWh/m(3) at 2h). No toxicity was detected for the treated ROC using Microtox() tests. Although the trihalomethane formation potential increased after the UVC/H(2)O(2) treatment, it was reduced to below that of the raw ROC after the biological treatment.