RMIT University
Browse

Lab-on-a-Chip imaging micro-echocardiography (i mu EC) for rapid assessment of cardiovascular activity in zebrafish larvae

journal contribution
posted on 2024-11-03, 15:35 authored by Nurul Hajar Mohd Fuad, Jan Kaslin, Donald WlodkowicDonald Wlodkowic
Analysis of physiological parameters using small model organisms is an attractive approach in pre-clinical drug discovery when studying effects of new drugs or existing drug combinations. Larval zebrafish (Danio rerio) is a small vertebrate model organism that recently emerged as an innovative experimental system for non-invasive and real-time analysis of physiological parameters such as cardiovascular activity. In this work, we demonstrate a new chip-enabled approach to perform non-invasive imaging micro-echocardiography (iμEC) on immobilized larval stages of zebrafish. The iμEC is a new assay for quantification of the temporal cardiac patterns based on analysis of video stream from a high-resolution camera. The chip-based system utilized hydrodynamic trapping principles to actively capture and immobilize individual larvae using a low-pressure suction for real-time iμEC analysis. The system coupled together with an integrated interface provided a new capability to rapidly assess pharmacologically-induced perturbation in cardiac function by real-time and non-invasive monitoring of zebrafish larvae. We demonstrated the application of the technology for proof-of-concept assessment of model cardio-active compounds delivered using continuous micro-perfusion. The optical transparency of larval stages and micro-hydrodynamic immobilization allowed for visualization of cardiac activity after drug treatment in real-time. Results obtained using micro-perfusion also enabl ed studies on rapid drug withdrawal that are difficult to achieve using existing protocols such as imaging in microtiter plates. This work demonstrates iμEC as a new technique for cardiological experiments utilizing zebrafish models.

Funding

Ecotoxicology-on-a-chip: towards smart devices in environmental biomonitoring

Australian Research Council

Find out more...

Safety of Lung Delivered Tissue Plasminogen Activator

United States Department of Health and Human Services

Find out more...

History

Journal

Sensors and Actuators, B: Chemical

Volume

256

Start page

1131

End page

1141

Total pages

11

Publisher

Elsevier

Place published

Netherlands

Language

English

Copyright

© 2017 Elsevier B.V.

Former Identifier

2006081360

Esploro creation date

2020-06-22

Fedora creation date

2018-01-24

Usage metrics

    Scholarly Works

    Exports

    RefWorks
    BibTeX
    Ref. manager
    Endnote
    DataCite
    NLM
    DC