RMIT University
Browse

Light sensors for objective light measurement in ambulatory polysomnography

journal contribution
posted on 2024-11-02, 06:19 authored by Rachel Schembri, Jo-Lene Spong, Allison Peters, Peter Rochford, Philip WilkschPhilip Wilksch, Fergal O'Donoghue, Kenneth Greenwood, Maree Barnes, Gerard KennedyGerard Kennedy, David Berlowitz
Ambulatory polysomnography (PSG) does not commonly include an objective measure of light to determine the time of lights off (Loff), and thus cannot be used to calculate important indices such as sleep onset latency and sleep efficiency. This study examined the technical specifications and appropriateness of a prototype light sensor (LS) for use in ambulatory Compumedics Somte PSG.Two studies were conducted. The first examined the light measurement characteristics of the LS when used with a portable PSG device, specifically recording trace range, linearity, sensitivity, and stability. This involved the LS being exposed to varying incandescent and fluorescent light levels in a light controlled room. Secondly, the LS was trialled in 24 home and 12 hospital ambulatory PSGs to investigate whether light levels in home and hospital settings were within the recording range of the LS, and to quantify the typical light intensity reduction at the time of Loff. A preliminary exploration of clinical utility was also conducted. Linearity between LS voltage and lux was demonstrated, and the LS trace was stable over 14 hours of recording. The observed maximum voltage output of the LS/PSG device was 250 mV, corresponding to a maximum recording range of 350 lux and 523 lux for incandescent and fluorescent light respectively. At the time of Loff, light levels were within the recording range of the LS, and on average dropped by 72 lux (9-245) in the home and 76 lux (4-348) in the hospital setting. Results suggest that clinical utility was greatest in hospital settings where patients are less mobile. The LS was a simple and effective objective marker of light level in portable PSG, which can be used to identify Loff in ambulatory P

History

Related Materials

  1. 1.
    DOI - Is published in 10.1371/journal.pone.0188124
  2. 2.
    ISSN - Is published in 19326203

Journal

PLoS ONE

Volume

12

Number

e0188124

Issue

11

Start page

1

End page

7

Total pages

7

Publisher

Public Library of Science

Place published

United States

Language

English

Copyright

© 2017 Schembri et al.

Former Identifier

2006082234

Esploro creation date

2020-06-22

Fedora creation date

2018-09-20

Usage metrics

    Scholarly Works

    Categories

    Keywords

    Exports

    RefWorks
    BibTeX
    Ref. manager
    Endnote
    DataCite
    NLM
    DC