Measuring the dose in bone for spine stereotactic body radiotherapy

journal contribution
posted on 2024-11-02, 16:47 authored by Maddison Shaw, Jessica Lye, Andrew Alves, Moshi GesoMoshi Geso
Purpose: Current quality assurance of radiotherapy involving bony regions generally utilises homogeneous phantoms and dose calculations, ignoring the challenges of heterogeneities with dosimetry problems likely occurring around bone. Anthropomorphic phantoms with synthetic bony materials enable realistic end-to-end testing in clinical scenarios. This work reports on measurements and calculated corrections required to directly report dose in bony materials in the context of comprehensive end-to-end dosimetry audit measurements (63 plans, 6 planning systems). Materials and methods: Radiochromic film and microDiamond measurements were performed in an anthropomorphic spine phantom containing bone equivalent materials. Medium dependent correction factors, kmed, were established using 6 MV and 10 MV Linear Accelerator Monte Carlo simulations to account for the detectors being calibrated in water, but measuring in regions of bony material. Both cortical and trabecular bony material were investigated for verification of dose calculations in dose-to-medium (Dm,m) and dose-to-water (Dw,w) scenarios. Results: For Dm,m calculations, modelled correction factors for cortical and trabecular bone in film measurements, and for trabecular bone in microDiamond measurements were 0.875(±0.1%), 0.953(±0.3%) and 0.962(±0.4%), respectively. For Dw,w calculations, the corrections were 0.920(±0.1%), 0.982(±0.3%) and 0.993(±0.4%), respectively. In the audit, application of the correction factors improves the mean agreement between treatment plans and measured microDiamond dose from −2.4%(±3.9%) to 0.4%(±3.7%). Conclusion: Monte Carlo simulations provide a method for correcting the dose measured in bony materials allowing more accurate comparison with treatment planning system doses. In verification measurements, algorithm specific correction factors should be applied to account for variations in bony material for calculations based on Dm,m and Dw,w.

History

Related Materials

  1. 1.
    DOI - Is published in 10.1016/j.ejmp.2021.03.011
  2. 2.
    ISSN - Is published in 11201797

Journal

Physica Medica

Volume

84

Start page

265

End page

273

Total pages

9

Publisher

Elsevier

Place published

United Kingdom

Language

English

Copyright

Crown Copyright © 2021 Published by Elsevier Ltd on behalf of Associazione Italiana di Fisica Medica. This is an open access article under the CCBY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).

Former Identifier

2006105964

Esploro creation date

2021-11-07

Usage metrics

    Scholarly Works

    Categories

    Exports

    RefWorks
    BibTeX
    Ref. manager
    Endnote
    DataCite
    NLM
    DC