RMIT University
Browse

Novel Technologies Found to be Valid and Reliable for the Measurement of Vertical Jump Height With Jump-and-Reach Testing

journal contribution
posted on 2024-11-02, 10:13 authored by Edward Brooks, Amanda Benson, Lyndell Bruce
Vertical jump testing is used by coaches and athletes across many sports and disciplines to assess lower-body power and neuromuscular fatigue. A range of devices are available to measure jump height, with recent innovations attempting to improve portability, usability, and accessibility. New devices should be evaluated for their effectiveness and dependability in specific tests before being adopted. The purpose of this study was to assess the validity and reliability of 2 novel measurement devices for jump height testing with a jump-and-reach protocol. Twenty-six healthy, active adults participated during 2 testing occasions. A wearable inertial measurement unit (VERT) and a smart device application (My Jump 2) were compared with established measures (force platform and jump-and-reach apparatus [Yardstick]). Correlations between the VERT and force platform were r = 0.95 (90% confidence interval [CI]: 0.93-0.97), and r = 0.93 (90% CI: 0.90-0.95) for the Yardstick. Correlations between the My Jump 2 app and force platform were r = 0.98 (90% CI: 0.97-0.99), and r = 0.94 (90% CI: 0.92-0.96) for the Yardstick. Reliability, measured as intraclass correlation coefficient (ICC), was 0.91 (90% CI: 0.87-0.94) for the VERT, and 0.97 (90% CI: 0.96-0.98) for the My Jump 2 app. Intrarater reliability for the My Jump 2 app was ICC = 0.99 (90% CI: 0.99-0.99). The VERT and the My Jump 2 app have both shown acceptable validity and reliability compared with both the force platform and Yardstick. However, practitioners should consider which measurement device/s to use based on the acceptable level of potential error for their population and testing objectives.

History

Related Materials

  1. 1.
    DOI - Is published in 10.1519/JSC.0000000000002790
  2. 2.
    ISSN - Is published in 15334287

Journal

Journal of strength and conditioning research

Volume

32

Issue

10

Start page

2838

End page

2845

Total pages

8

Publisher

Lippincott Williams & Wilkins

Place published

United States

Language

English

Copyright

© 2018 National Strength and Conditioning Association

Former Identifier

2006090540

Esploro creation date

2020-06-22

Fedora creation date

2019-05-23

Usage metrics

    Scholarly Works

    Exports

    RefWorks
    BibTeX
    Ref. manager
    Endnote
    DataCite
    NLM
    DC