Technical note: Extended longitudinal and lateral 3D imaging with a continuous dual-isocenter CBCT scan

journal contribution
posted on 2024-11-03, 09:18 authored by Tess Reynolds, Sepideh Hatamikia, Yiqun Ma, Owen Dillon, Grace Gang, J. Webster Stayman, Ricky O'BrienRicky O'Brien
Background: The clinical benefits of intraoperative cone beam CT (CBCT) during orthopedic procedures include (1) improved accuracy for procedures involving the placement of hardware and (2) providing immediate surgical verification. Purpose: Orthopedic interventions often involve long and wide anatomical sites (e.g., lower extremities). Therefore, in order to ensure that the clinical benefits are available to all orthopedic procedures, we investigate the feasibility of a novel imaging trajectory to simultaneously expand the CBCT field-of-view longitudinally and laterally. Methods: A continuous dual-isocenter imaging trajectory was implemented on a clinical robotic CBCT system using additional real-time control hardware. The trajectory consisted of 200 degrees circular arcs separated by alternating lateral and longitudinal table translations. Due to hardware constraints, the direction of rotation (clockwise/anticlockwise) and lateral table translation (left/right) was reversed every 400 degrees. X-ray projections were continuously acquired at 15 frames/s throughout all movements. A whole-body phantom was used to verify the trajectory. As comparator, a series of conventional large volume acquisitions were stitched together. Image quality was quantified using Root Mean Square Deviation (RMSD), Mean Absolute Percentage Deviation (MAPD), Structural Similarity Index Metric (SSIM) and Contrast-to-Noise Ratio (CNR). Results: The imaging volume produced by the continuous dual-isocenter trajectory had dimensions of L = 95 cm x W = 45 cm x H = 45 cm. This enabled the hips to the feet of the whole-body phantom to be captured in approximately half the imaging dose and acquisition time of the 11 stitched conventional acquisitions required to match the longitudinal and lateral imaging dimensions. Compared to the stitched conventional images, the continuous dual-isocenter acquisition had RMSD of 4.84, MAPD of 6.58% and SSIM of 0.99. The CNR of the continuous dual-isocenter and stitched conventional acquisitions were 1.998 and 1.999, respectively. Conclusion: Extended longitudinal and lateral intraoperative volumetric imaging is feasible on clinical robotic CBCT systems.

History

Related Materials

  1. 1.
    DOI - Is published in 10.1002/mp.16234
  2. 2.
    ISSN - Is published in 00942405

Journal

Medical Physics

Volume

50

Issue

4

Start page

2372

End page

2379

Total pages

8

Publisher

Wiley-Blackwell Publishing, Inc.

Place published

United States

Language

English

Copyright

© 2023 The Authors. This is an open access article under the terms of the Creative Commons Attribution License.

Former Identifier

2006122645

Esploro creation date

2023-06-16

Usage metrics

    Scholarly Works

    Licence

    Exports

    RefWorks
    BibTeX
    Ref. manager
    Endnote
    DataCite
    NLM
    DC