Theoretical and experimental estimation of limiting input heat flux for thermoelectric power generators with passive cooling

journal contribution
posted on 2024-11-01, 19:02 authored by Ashwin Shridhar Date, Abhijit Shridhar DateAbhijit Shridhar Date, Christopher Dixon, Randeep Singh, Aliakbar AkbarzadehAliakbar Akbarzadeh
This paper focuses on theoretical and experimental analysis used to establish the limiting heat flux for passively cooled thermoelectric generators (TEG). 2 commercially available TEG's further referred as type A and type B with different allowable hot side temperatures (150°C and 250°C respectively) were investigated in this research. The thermal resistance of TEG was experimentally verified against the manufacturer's specifications and used for theoretical analysis in this paper. A theoretical model is presented to determine the maximum theoretical heat flux capacity of both the TEG's. The conventional methods are used for cooling of TEG's and actual limiting heat flux is experimentally established for various cold end cooling configurations namely bare plate, finned block and heat pipe with finned condenser. Experiments were performed on an indoor setup and outdoor setup to validate the results from the theoretical model. The outdoor test setup consist of a fresnel lens solar concentrator with manual two axis solar tracking system for varying the heat flux, whereas the indoor setup uses electric heating elements to vary the heat flux and a low speed wind tunnel blows the ambient air past the device to simulate the outdoor breezes. It was observed that bare plate cooling can achieve a maximum heat flux of 18,125W/m2 for type A and 31,195W/m2 for type B at ambient wind speed of 5m/s while maintaining respective allowable temperature over the hot side of TEG's. Fin geometry was optimised for the finned block cooling by using the fin length and fin gap optimisation model presented in this paper. It was observed that an optimum finned block cooling arrangement can reach a maximum heat flux of 26,067W/m2 for type A and 52,251W/m2 for type B TEG at ambient wind speed of 5m/s of ambient wind speed. The heat pipe with finned condenser used for cooling can reach 40,375W/m2 for type A TEG and 76,781W/m2 for type B TEG.

History

Related Materials

  1. 1.
    DOI - Is published in 10.1016/j.solener.2014.10.043
  2. 2.
    ISSN - Is published in 0038092X

Journal

Solar Energy

Volume

111

Start page

201

End page

217

Total pages

17

Publisher

Elsevier Ltd

Place published

United Kingdom

Language

English

Copyright

© 2014 Elsevier Ltd. All rights reserved.

Former Identifier

2006051933

Esploro creation date

2020-06-22

Fedora creation date

2015-04-22

Usage metrics

    Scholarly Works

    Exports

    RefWorks
    BibTeX
    Ref. manager
    Endnote
    DataCite
    NLM
    DC